13 products found in Street lights:

HSW 2209 cable fuse box

Pole internal diameter: from ∅ 106 mm
Measurements: 290 x 84 x 92 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

The HSW 2209 cable junction box is based on the 22 series housing.

HSW 2209 cable fuse box

HSW 2210 cable fuse box

Pole internal diameter: from ∅ 89 mm
Fuses: 2 x D01 (E14) up to 16 A
Measurements: 290 x 84 x 72 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

VDE tested according to DIN VDE 0660-505 and DIN 43628

HSW 2210 cable fuse box

HSW 2220 cable fuse box

Pole internal diameter: from ∅ 89 mm
Fuses: 2 x D01 (E14) up to 16 A
Measurements: 290 x 84 x 72 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²
Also available with surge protection!

VDE tested according to DIN VDE 0660-505 and DIN 43628

HSW 2220 cable fuse box

HSW 2230 cable fuse box

Pole internal diameter: from ∅ 89 mm
Fuses: 3 x D01 (E14) up to 16 A
Measurements: 290 x 84 x 72 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²
Also available with surge protection!

VDE tested according to DIN VDE 0660-505 and DIN 43628

HSW 2230 cable fuse box

HSW 2309 cable fuse box

Pole internal diameter: from ∅ 106 mm
Measurements: 265 x 84 x 92 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

The cable junction box HSW 2309 is based on the housing of the 23 series.

HSW 2309 cable fuse box

HSW 2310 cable fuse box

Pole internal diameter: from ∅ 89 mm
Fuses: 2 x D01 (E14) up to 16 A
Measurements: 265 x 84 x 72 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

VDE tested according to DIN VDE 0660-505 and DIN 43628

HSW 2310 cable fuse box

HSW 2320 cable fuse box

Pole internal diameter: from ∅ 89 mm
Fuses: 2 x D01 (E14) up to 16 A
Measurements: 265 x 84 x 72 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²
Also available with surge protection!

VDE tested according to DIN VDE 0660-505 and DIN 43628

HSW 2320 cable fuse box

HSW 2330 cable fuse box

Pole internal diameter: from ∅ 89 mm
Fuses: 3 x D01 (E14) up to 16 A
Measurements: 265 x 84 x 72 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

VDE tested according to DIN VDE 0660-505 and DIN 43628

HSW 2330 cable fuse box

HSW 2500 / 2505 cable fuse box

Pole internal diameter: from ∅ 89 (HSW 2500); from ∅ 95 (HSW 2505) mm
Measurements: 340 x 84 x 72 (HSW 2500); 340 x 84 x 79 (HSW 2505) mm

The cable junction boxes HSW 2500 and HSW 2505 are based on the housing of the 25 series.

HSW 2500/2505 cable fuse box

HSW 2509 cable fuse box

Pole internal diameter: from ∅ 106 mm
Measurements: 340 x 84 x 92 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

The cable junction boxes HSW 2509 is based on the housing of the 25 series.

HSW 2509 cable fuse box

HSW 2520 / 2525 / 2529 cable fuse box

Pole internal diameter: from ∅ 89 (HSW 2520); from ∅ 95 (HSW 2525); from ∅ 106 (HSW 2529) mm
Fuses: 2 x D01 (E14) up to 16 A
Measurements: 340 x 84 x 72 (HSW 2520); 340 x 84 x 79 (HSW 2525); 340 x 84 x 92 (HSW 2529) mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²
Also available with surge protection!

The cable junction boxes HSW 2520, HSW 2525 and HSW 2529 are based on the housing of the 25 series.

HSW 2520/2525/2529 cable fuse box

HSW 2530 / 2535 / 2539 cable fuse box

Pole internal diameter: from ∅ 89 (HSW 2530); from ∅ 95 (HSW 2535); from ∅ 106 (HSW 2539) mm
Fuses: 3 x D01 (E14) up to 16 A
Measurements: 340 x 84 x 72 (HSW 2530); 340 x 84 x 79 (HSW 2535); 340 x 84 x 92 (HSW 2539) mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²
Also available with surge protection!

The cable junction boxes HSW 2530, HSW 2535 and HSW 2539 are based on the housing of the 25 series.

HSW 2530/2535/2539 cable fuse box

HSW 2537 cable fuse box

Pole internal diameter: from ∅ 95 mm
Fuses: 3 x D01 (E14) up to 16 A
Measurements: 340 x 84 x 92 mm
Connection: 3 cables 5 x 6 mm² up to 5 x 16 mm²

The cable junction box HSW 2537 is based on the housing of the 25 series.

HSW 2537 cable fuse box

You need something more individual?

HSW Stadtfeld has a varied range of cable junction boxes. Should you still not find the right solution for your requirements, we can adapt our cable junction boxes individually to your wishes.

We have the possibility to equip our models with different seals, screw connections, earth conductors and fuse inserts. Our variety of housings allows us to realize numerous installations, be it residual current circuit breakers, surge protection modules, light controls or control lines. We would be pleased to advise you and develop an individual solution for you.

Just contact us!

Any questions?

Just give us a call or send us an email.

Cable junction boxes

Your contact person

Christian Tilch
Office duty
Phone +49 2192 9166 0

hsw@hsw-stadtfeld.de

Pole mount sockets

Your contact person

Christian Tilch
Office duty
Phone +49 2192 9166 0

hsw@hsw-stadtfeld.de

Control technology

Your contact person

Michael Mach
Office duty
Phone +49 2192 9166 0

hsw@hsw-stadtfeld.de

Light

Your contact person

Michael Mach
Office duty
Phone +49 2192 9166 0

hsw@hsw-stadtfeld.de